{"product_id":"em10-avr-generator-parts-automatic-voltage-regulator-stabilizer-control-board","title":"EM10 AVR Generator Parts  Automatic Voltage Regulator Stabilizer Control Board","description":"\u003cdiv class=\"a-row feature\" data-feature-name=\"productDescription\" data-template-name=\"productDescription\" id=\"productDescription_feature_div\"\u003e\n\u003cdiv class=\"a-divider a-divider-section\"\u003e\n\u003cdiv class=\"a-divider-inner\"\u003e \u003c\/div\u003e\n\n\u003ch1\u003e\u003cspan dir=\"auto\" style=\"vertical-align:inherit;\"\u003e\u003cspan dir=\"auto\" style=\"vertical-align:inherit;\"\u003e EM10 AVR Generator Parts  Automatic Voltage Regulator Stabilizer Control Board \u003c\/span\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\n\u003cdiv class=\"a-section a-spacing-small\" id=\"productDescription\"\u003e\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-size:14px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:宋体;color:black;\"\u003e•\u003c\/span\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;\"\u003e Over-excitation protection – limit can be adjusted via a potentiometer (IEXC.)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-size:14px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:宋体;color:black;\"\u003e•\u003c\/span\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;\"\u003e Green status LED indicating unit is powered on\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-size:14px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:宋体;color:black;\"\u003e•\u003c\/span\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;\"\u003e Red status LED indicating excitation current limiting\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eWhen used with EMCP 4.3\/4.4 and IVR-compatible EMCP 4.1\/4.2 controllers, the Integrated Voltage Regulator system\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-size:14px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:宋体;color:black;\"\u003e•\u003c\/span\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;\"\u003e Automatic Voltage Regulation (AVR)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-size:14px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:宋体;color:black;\"\u003e•\u003c\/span\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;\"\u003e Programmable stability settings\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-size:14px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:宋体;color:black;\"\u003e•\u003c\/span\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;\"\u003e Soft start control with an adjustable time setting in\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eAVR control mode\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-size:14px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:宋体;color:black;\"\u003e•\u003c\/span\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;\"\u003e Dual Slope Under Frequency (Volts \/ Hz) regulation\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-size:14px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:宋体;color:black;\"\u003e•\u003c\/span\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;\"\u003e Three-phase or single-phase generator voltage (RMS) sensing\/regulation in AVR mode\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eEMCP 4.3\/4.4 and IVR-compatible EMCP 4.2 controllers also offer:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-size:14px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:宋体;color:black;\"\u003e•\u003c\/span\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;\"\u003e Power Factor Regulation (PF)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-size:14px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:宋体;color:black;\"\u003e•\u003c\/span\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;\"\u003e Generator paralleling with reactive droop compensation\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-size:14px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:宋体;color:black;\"\u003e•\u003c\/span\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;\"\u003e Line drop compensation\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-size:14px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;background-color:#FFFFFF;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eELECTRICAL\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;background-color:#FFFFFF;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eGenerator Excitation Types Self Excitation \/ Internal Excitation \/ Permanent Magnet (PMG)\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;background-color:#FFFFFF;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eMax. Continuous Field Current Output 6 Amps\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;background-color:#FFFFFF;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eMax. Forcing Field Current Output 10 Amps\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;background-color:#FFFFFF;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eMax. AC Voltage Input (X1:X2, Z1:Z2) 180 Vrms\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;background-color:#FFFFFF;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eENVIRONMENTAL\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;background-color:#FFFFFF;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eOperating Temperature Range −40 °C (−40 °F) to +70 °C (+158 °F)\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;background-color:#FFFFFF;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eStorage Temperature Range −40 °C (−40 °F) to +85 °C (+185 °F)\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;background-color:#FFFFFF;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eRelative Humidity Tolerance 95% non-condensing humidity\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;background-color:#FFFFFF;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eSalt Spray 5% salt (NaCl) solution for 120 hrs\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;background-color:#FFFFFF;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eVibration 4.5 G-rms, 24-2000 Hz in 3 orthogonal planes\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;background-color:#FFFFFF;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eElectromagnetic Compatibility RF Immunity (Radiated \u0026amp; Conducted)\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;background-color:#FFFFFF;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eRF Emissions (Radiated \u0026amp; Conducted)\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;background-color:#FFFFFF;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eElectrical Transients\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;background-color:#FFFFFF;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003eWeight 770 g ± 30 g\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-size:14px;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"box-sizing:border-box;margin:0px;color:#555555;font-family:Arial, Helvetica, sans-serif;font-size:12.8px;background-color:#FFFFFF;\"\u003e\u003cspan style=\"box-sizing:border-box;font-family:Arial, sans-serif;color:black;font-size:14px;\"\u003ePower Consumption (at Max. Continuous Rating) \u0026lt;450 VA\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:16px;\"\u003e \u003cdiv\u003e\u003cimg cke-id=\"img37\" referrerpolicy=\"no-referrer\" src=\"https:\/\/i.ebayimg.com\/00\/s\/MTYwMFgxNjAw\/z\/mccAAeSw5FNpCx2R\/$_10.JPG?set_id=880000500F\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg cke-id=\"img38\" referrerpolicy=\"no-referrer\" src=\"https:\/\/i.ebayimg.com\/00\/s\/MTYwMFgxNjAw\/z\/jcEAAeSw~M1pCx2T\/$_10.JPG?set_id=880000500F\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg cke-id=\"img39\" referrerpolicy=\"no-referrer\" src=\"https:\/\/i.ebayimg.com\/00\/s\/MTYwMFgxNjAw\/z\/cpcAAeSwbGRpCx2W\/$_10.JPG?set_id=880000500F\"\u003e\u003c\/div\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Used to set table width because AUI is overriding the width attribute of the tables coming in description --\u003e\n\u003cstyle type=\"text\/css\"\u003e#productDescription h3 {\n            margin: 0.75em 0px 0.375em -1px;\n        }\n\u003c\/style\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Wespc Technologies","offers":[{"title":"Default Title","offer_id":43490525937782,"sku":"EM10","price":470.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0591\/5996\/9910\/files\/9e4bdb1e3949ebb18eb9bd13f2b0e835.jpg?v=1780903409","url":"https:\/\/www.wespcshop.com\/products\/em10-avr-generator-parts-automatic-voltage-regulator-stabilizer-control-board","provider":"Wespc Technologies","version":"1.0","type":"link"}