Original Smartgen HGM180HC Manual Start Generator Controller
Original Smartgen HGM180HC Manual Start Generator Controller
السعر العادي
$188.62 USD
السعر العادي
$210.00 USD
سعر البيع
$188.62 USD
سعر الوحدة
/
لكل
يتم احتساب الشحن عند الخروج.
لم نتمكن من تحميل توفر الاستلام
Original Smartgen HGM180HC Manual Start Generator Controller
The Model 180/180hc is an Automatic Engine Control Module. The module is used to automatically start and stop the engine, indicating the operational status and fault conditions, automatically shutting down the engine and indicating the engine failure by LED on the front panel.
HGM180hc append a LCD hours count that base on HGM180.
OPERATION
If you use hgm180 for the first time , configure is necessary. If you want to configure the module ,please look Configuration. Operation of the module is via a three position key switch mounted on the front panel with OFF(O), STARTand AUTO positions. In the 'O' position the output are de-energized.
Manual Operation:
1. Select manual run
2. Depress pre-heat button for required length of time
3. Press START to crank engine
Once the Start button is pressed and maintained, the engine fuel system is energized. The 'Crank' output is then energized and the starter motor operated, disengaging automatically when the engine fires or when the 'Start' button is released. The protection hold-off timer is then initiated.
Automatic Operation:
1. Select AUTO
2. When Remote Start is active, the generator will automatic start.
Operation of any of the following alarms (which are close on fault) will cause the run output to de-energize:
. Low Oil Pressure
. High Engine Temperature
. Auxiliary Shutdown
. Over speed
The Model 180/180hc is an Automatic Engine Control Module. The module is used to automatically start and stop the engine, indicating the operational status and fault conditions, automatically shutting down the engine and indicating the engine failure by LED on the front panel.
HGM180hc append a LCD hours count that base on HGM180.
OPERATION
If you use hgm180 for the first time , configure is necessary. If you want to configure the module ,please look Configuration. Operation of the module is via a three position key switch mounted on the front panel with OFF(O), STARTand AUTO positions. In the 'O' position the output are de-energized.
Manual Operation:
1. Select manual run
2. Depress pre-heat button for required length of time
3. Press START to crank engine
Once the Start button is pressed and maintained, the engine fuel system is energized. The 'Crank' output is then energized and the starter motor operated, disengaging automatically when the engine fires or when the 'Start' button is released. The protection hold-off timer is then initiated.
Automatic Operation:
1. Select AUTO
2. When Remote Start is active, the generator will automatic start.
Operation of any of the following alarms (which are close on fault) will cause the run output to de-energize:
. Low Oil Pressure
. High Engine Temperature
. Auxiliary Shutdown
. Over speed