Original Smartgen MGC120 LED Display Auto Start/Stop Genset Generator Controller Compatible with SmartGen MGC120 AMF ATS Switching Control Panel Single Genset Module

Wide Application Range

Household portable single-phase gasoline backup generator cabinet, small commercial retail shop emergency power unit, construction engineering mini portable genset, outdoor camping silent petrol generator control panel, gas small generator automation equipment, generator repair factory mini genset aftermarket replacement parts, low-cost single-phase AMF automatic transfer power distribution projects without remote data monitoring.

Product Specifications

  • Brand: SmartGen (众智)
  • Model: MGC120
  • Core Function: Single-phase gasoline genset AMF automatic mains failure controller, DC12V dedicated, LED digital display, auto start-stop ATS control, multi fault protection (No RS485, No CAN J1939, No CT power metering, Single-phase only)
  • Working Power Supply: DC12V lead-acid battery power only
  • AC Sampling Standard: Single-phase 1P2W dual-source (Mains + Generator) AC30~360V voltage sampling
  • Communication Interfaces: Front LINK PC debug port only (No RS485, No CAN bus)
  • Display: 4-group high-brightness red LED digital tube + independent fault indicator lights
  • Panel Cutout Size: 78 × 66 mm, overall dimension 95 × 86 × 46.5 mm
  • Front Panel Protection Grade: IP55 dustproof & waterproof sealing panel
  • Operating Temperature: -25℃ ~ +70℃
  • Net Weight: 0.2KG
  • Warranty: 12 months genuine factory warranty
  • Certifications: CE, ISO9001, EMC

Common Equipment Failures Solved

  • LED no display after power on: Confirm battery voltage strictly DC12V, positive and negative wiring reversed check
  • Genset no auto startup when mains lost: Adjust mains abnormal detection delay threshold, recheck MV mains sampling wiring
  • Startup cycle 3 times and lock protection: Check fuel cut relay wiring, battery power insufficient, engine spark plug fault
  • ATS breaker cannot auto close: Reconfigure auxiliary output function as GCB close signal via panel parameter
  • Need remote mobile APP monitoring: MGC120 without RS485 port, upgrade to MGC320 with Modbus communication
  • Need three-phase generator matching: MGC120 only single-phase sampling, select MGC320 three-phase version
  • Need power consumption kWh statistics: MGC120 no CT input, install external single-phase power meter separately