Original HAT600 SMARTGEN Automatic transfer switch controller Generator Control Module
Overview:
HAT600 series ATS controller is intelligent dual-supply module with programmable function, automatic measurement, LCD display, and digital communication. It combines digital intelligence and networking. Automatic measurement and control can reduce incorrect operation. It is an ideal option for ATS.
HAT600 series ATS controller is made of microprocessor as its core, can accurately detect extended-spectrum 2-way-3-phase voltage and also make accurate judgment and output passive control switch under the abnormal voltage (over and under voltage, miss phase and over and under frequency). This controller has full consideration in various application of ATS (automatic transfer system) can be directly used for Intelligent ATS, Contactor ATS, Circuit Break ATS etc. It have compact structure, advanced circuits, simple wiring and high reliability, be widely used in electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, electrical devices, automatic control and testing system etc.
Overview:
HAT600 series ATS controller is intelligent dual-supply module with programmable function, automatic measurement, LCD display, and digital communication. It combines digital intelligence and networking. Automatic measurement and control can reduce incorrect operation. It is an ideal option for ATS.
HAT600 series ATS controller is made of microprocessor as its core, can accurately detect extended-spectrum 2-way-3-phase voltage and also make accurate judgment and output passive control switch under the abnormal voltage (over and under voltage, miss phase and over and under frequency). This controller has full consideration in various application of ATS (automatic transfer system) can be directly used for Intelligent ATS, Contactor ATS, Circuit Break ATS etc. It have compact structure, advanced circuits, simple wiring and high reliability, be widely used in electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, electrical devices, automatic control and testing system etc.
Key Technical Specifications
- · Brand: SmartGen
- · Model: HAT600
- · Power Supply: Single DC 8~35V wide battery voltage (12V/24V universal, no AC self-power)
- · Display: 128×64 Backlight Segment LCD, Chinese & English bilingual switchable
- · Front Protection Grade: IP55 with silicone sealing gasket, IP42 without gasket
- · Voltage Sampling: Dual 3-phase 3/4 wire / single-phase 2-wire, max 625V line voltage, 50/60Hz auto adapt
- · Current Sampling: Not supported (no CT interface)
- · Digital Input: 4 programmable DI terminals (fire trip, ATS position feedback)
- · Relay Output: 6 passive AC250V relays (16A heavy-duty S1/S2 close output)
- · Communication: Isolated RS485 Modbus-RTU + LINK debug port (SG72A adapter required)
- · Fault Storage: 99 timestamped fault event logs
- · Core Special Functions: Fire forced neutral trip, scheduled genset weekly test, flexible ATS transfer logic
- · Supported ATS Switch: 2-stage & 3-position 0/1/2 breaking ATS
- · Dimension: 209×153×55mm, Panel Cutout: 186×141mm
- · Operating Temp: -25℃ ~ +70℃
- · Certifications: CE, EMC
- · Warranty: 12 months genuine factory warranty
Core Functions
- Complete Multi-Dimensional Power Fault Protection
Overvoltage, undervoltage, phase loss, reverse phase sequence, overfrequency, underfrequency, ATS close/open failure alarm & lockout protection.
- Flexible ATS Transfer Logic
Auto-recovery / non-auto-recovery transfer, master-backup dual genset rotation, weekly scheduled genset test (loaded/unloaded), reclosing & re-lock function.
- Fire Protection Mandatory Trip
Passive fire alarm signal input, automatically switch ATS to neutral zero position to cut all load, fully compliant with fire power distribution acceptance standards.
- Remote Three-Remote Monitoring
RS485 Modbus RTU realizes remote control, remote measurement & remote signaling via 4G/WIFI DTU upper computer cloud platform.
- Operation Maintenance Data Management
Real-time clock, 99 fault history logs, total ATS switch count, dual power running hour statistics, scheduled maintenance reminder alarm.
Matching Equipment
- 2-stage / 3-position PC/CB/CC class ATS automatic transfer switch
- SG72A communication adapter for local PC parameter editing
- 4G RS485 DTU module for remote cloud monitoring
- SmartGen BAC1210/BAC2410 battery float charger for cabinet DC power supply
- HWS560 AC-DC power module (for cabinet without storage battery