Original Mebay DT3000 MK2 replaced by DT4000G Generator Cloud Remote Controller Control Panel
Main Features:
1. Connect generator controller to the Internet, realizing remote real-time monitoring of the generator set by PC and App.
2. Remote controll generator
3. Remote monitor data
4. Remote fault analyze
5. Real-time locate, maintain and manage generator set.
Main Features:
1. Connect generator controller to the Internet, realizing remote real-time monitoring of the generator set by PC and App.
2. Remote controll generator
3. Remote monitor data
4. Remote fault analyze
5. Real-time locate, maintain and manage generator set.
Product Specifications
- Brand: Mebay
- Model: DT3000 MK2
- Core Function: Multi-genset parallel synchronization + mains grid peak shaving control, substitute DeepSea DT3000 MK2
- DC Power Supply: DC 8V ~ 36V, standby power ≤1.8W
- AC Sampling: 3-phase 0~600V L-L, auto 50/60Hz
- Current Measurement: CT 5A secondary, full 3-phase power parameter calculation
- Communication Interfaces: Front USB, Isolated RS485 Modbus RTU, CANbus J1939
- Relay Output Rating: 8A 250VAC volt-free programmable contacts
- Panel Cutout Size: 222 × 156 mm
- Overall Dimension: 236 × 170 × 54 mm
- Operating Temperature: -20℃ ~ +70℃
- Front Panel Protection: IP65 waterproof & dustproof with rubber sealing gasket
- Warranty: 12 months genuine factory warranty
Wide Application Range
Industrial multi-generator fixed power stations, data center backup parallel gensets, mining off-grid power supply, commercial building peak shaving standby power, marine multi-unit parallel generator systems, municipal emergency power stations, large construction site diesel generator groups, compatible with Cummins, Perkins, Volvo and other ECU-controlled diesel engines.
Common Equipment Failures Solved
- Uneven load distribution of parallel generators: PID gain parameter setting error, CT current transformer wiring reversed
- Failed to synchronize with mains grid: Mains and generator phase sequence inconsistent, voltage/frequency threshold parameter wrong
- Onboard relay burnt when driving glow plug: Onboard contact capacity limited to 8A, install external Hongfa HAT700BI 70A heavy relay for current amplification
- Laptop cannot connect controller for debugging: Use SG72A RS485 conversion adapter, check A/B wiring reversal and baud rate matching
- No engine data displayed on CAN J1939 channel: CAN-H/CAN-L wiring reversed, engine ECU communication protocol mismatch
- Frequent reverse power protection shutdown during grid parallel operation: Grid parallel phase angle threshold set too sensitive, genset governor response lag