Skip to product information
1 of 7

Wespc Technologies

Original Genuine SmartGen HAT600NB Intelligent Dual Power Supply Module Generator ATS Controller

Original Genuine SmartGen HAT600NB Intelligent Dual Power Supply Module Generator ATS Controller

Regular price $398.00 USD
Regular price $450.00 USD Sale price $398.00 USD
Sale Sold out
Shipping calculated at checkout.
Genuine SmartGen HAT600NB Intelligent Dual Power Supply Module Generator ATS Controller
 

Specifications

  • · Brand: SmartGen
  • · Model: HAT600NB
  • · Power Supply: Redundant DC8~35V + Dual AC L-N 160~280V self-power
  • · Display: 128×64 Backlight LCD, Chinese & English bilingual switchable
  • · Front Protection Grade: IP55 with silicone sealing gasket
  • · Voltage Sampling: Dual 3-phase 4-wire / single-phase 2-wire (3P3W not supported)
  • · Frequency Range: 50/60Hz auto adaptive
  • · Digital Input: 4 programmable DI terminals (fire trip, ATS position feedback)
  • · Relay Output: 6 passive AC250V relays (16A heavy-duty S1/S2 close output)
  • · Communication: Isolated RS485 Modbus-RTU + LINK debug port (SG72A adapter required)
  • · Fault Storage: 200 timestamped fault event logs
  • · Special Core Function: Fire protection forced neutral trip, scheduled genset weekly test
  • · Supported ATS Switch: 2-stage & 3-position 0/1/2 breaking ATS
  • · Dimension: 209×153×55mm, Panel Cutout: 186×141mm
  • · Operating Temp: -25℃ ~ +70℃
  • · Certifications: CE, EMC
  • · Warranty: 12 months genuine factory warranty


Core Functions

  1. Redundant Dual Power Supply
    DC battery and two independent AC mains power supply work simultaneously; controller keeps running when single power source loses power, maximize reliability for critical loads.
 
  1. Complete Multi-Dimensional Power Fault Protection
    Overvoltage, undervoltage, phase loss, reverse phase sequence, overfrequency, underfrequency, ATS close/open failure alarm & lockout protection.
 
  1. Flexible ATS Transfer Logic
    Auto-recovery / non-auto-recovery transfer, master-backup dual genset rotation, weekly scheduled genset test (loaded/unloaded), reclosing & re-lock function.
 
  1. Fire Protection Mandatory Trip
    Passive fire alarm signal input, automatically switch ATS to neutral zero position to cut all load, fully compliant with fire power distribution acceptance standards.
 
  1. Remote Three-Remote Monitoring
    RS485 Modbus RTU realizes remote control, remote measurement & remote signaling via 4G/WIFI DTU upper computer cloud platform.
 
  1. Operation Maintenance Data Management
    Real-time clock, 200 fault history logs, total ATS switch count, dual power running hour statistics, scheduled maintenance reminder alarm.
 
Matching Equipment
  1. 2-stage / 3-position PC/CB/CC class ATS automatic transfer switch
  2. SG72A communication adapter for local PC parameter editing
  3. 4G RS485 DTU module for remote cloud monitoring
  4. SmartGen BAC1210/BAC2410 battery float charger for cabinet DC power supply

View full details